QLS-8100 Xe 3-9
6 Press the + or - key until Gap is displayed.
7 Press the SELECT key. The display will show the following prompt:
8 Press and hold the FORM FEED/ADVANCE key until the liner is inside
the sensor bracket. On notched media, temporarily slide the media out so
that it is completely clear of the sensor assembly.
9 Press the SELECT key. The display will show the following prompt:
10 Press and hold the FORM FEED/ADVANCE key until the next label is
inside the Gap sensor.
11 Press the SELECT key. The display will show the following prompt:
12 Press and hold the FORM FEED/ADVANCE key until the next gap is
positioned behind the Media Sensor Assembly and in close proximity to
the guide arrow indicated on the center plate.
13 Press the SELECT key and observe the gap size on the display. The gap
size should be the same as the measured gap of your media and the
following message will be displayed:
Gap
Calibration OK
Place Gap @ Arrow
Then Press Select
Place Media @ Sensor
Then Press Select
Place Liner @ Sensor
Then Press Select
Calibrate
Gap